Home›Products› Bitumen And Asphalt Testing Lab Equipment
Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Benkelman Beam, Bitumen Centrifuge Extractor, Digital Penetrometer, Ductility Testing Apparatus, Hand Operated Bitumen Extractor, Kinematic Viscometer Bath, Marshall Stability Test Apparatus, Saybolt Viscometer, Standard Penetrometer, Standard Tar Viscometer and Stripping Value Apparatus from Ghaziabad.
specifications and also per is 1448 (p: 60) & (p: 93) this apparatus is used for penetration test on a wide variety of materials. It consists of a head support mounted on a vertical rod which can be adjusted for height. A rack and pinion and pointer assembly provides fine adjustment of needle tip to sample and in corporate a slipping clutch mechanism which make reading of penetration and subsequent resetting a sample and accurate operation. The dial graduate from 0-400 in one tenth millimeter sub-division. The instrument is supplied with two sample containers & 2 wts.
Penetrometer apparatus with containers and weights having penetration needle (Bitumen)
Penetrometer apparatus with containers and weights having penetration CONE HOLLOW type (Grease)
same as above – but with Geared arrangement for moving the arm with geared unit.
Penetrometer with Brass Cone & Needle with DIGITAL TIMER DEVICE (Adjustable)
--- same as above—but with geared arrangement for moving the arm with geared unit.
Salient Features
Optional Accessories
Spare Penetration Needle (Pack of two)
Spare Penetration solid cone
Spare Penetration brass hollow cone
Grease worker hand operated
Grease worker hand operated big handle (Lever type)
Ductility Testing Machine is defined as the distance in cms to which a standard briquette of bitumen can be stretched before the thread breaks. The briquette is stretched at a rate of 50 mm /min. /2.5 mm per minute at a temperature of 27ºC /0.5ºC.The apparatus consists of the water bath with a thermostatic heater and a circulating pump to maintain uniform water temperature One half of the briquette molds is fixed on a fixed plate in the water bath, the other half of the briquette mold is fixed to a carrier which slides over a rotating the threaded shaft with a clutch. The motor and gears to rotate the shaft are housed in a cabinet fixed above the other end of the bath. A pointer fixed to the carrier moves over a scale graduated from 0-110 cm x 1 mm fixed on the bath with 0 (Zero) of the scale towards the fixed plates side. The rotating shaft has 2 speeds of travel for the bracket, 5 cm/min and 1 cm/min. selected by a clutch. Water bath inside is aluminum/ S. steel, it is an insulated water bath Water bath is provided with a drain. A heater with thermostatic control is fixed inside the water bath. Control switches for motor pump heater and indicator lamps are fixed at a convenient place on the water bath. Complete with three briquette molds and one base plate, steel all made of brass operates on 230V A.C. supply single phase.
This instrument is used for determination and checking of bitumen percentage in bituminous mix. The mix is added with a solvent and dissolved bitumen is removed by centrifugal action. Consists of a removable aluminium rotor bowl, capacity 1500 gms. This shaft and thus the bowl is rotated fast manually by enclosed gears in the cast body and handle. Solvent is introduced during the test through the holes in the cap of the housing. A drain is provided to collect dissolved bitumen coming out of the rotating bowl and getting collected in the housing.
Microprocessor based circuitry assures precise, reliable temperature control within specified tolerances throughout the operating range of the bath i.e. 10 °C to ambient temperature.
Dual digital displays show set and actual bath temperature
Simple push button controls and digital display permit easy setting and monitoring of bath temperature.
Bath accommodates 04 Nos glass capillary reversion viscometers of various types at a time
Viewing the viscometers is made easy by glare‑free fluorescent illumination.
Temperature control uniformity is assured by means of motorized stirrer, which provides complete circulation without turbulence.
Frost free glass window for low temperature bath
Control panel is mounted on a side of the bath
Complete exterior body is finished with attractive powder coated paint
Technical Specifications of Refrigeration System :
Refrigeration system : Emerson/Danfoss Make refrigeration system
Compressor: Hermetically Sealed Compressor
Condenser : Fin & Tube type Air‑Cooled Condenser
Refrigerant : R134a
Optional Accessories At Extra Cost :
Voltage Stabilizer(Highly recommended)
Temperature calibration certificate as per ISO/IEC : 17025 (NABL)
Display resolution 0.01°C with Eurotherm Make Controller
Thermometer glass ‑ IP 30C (‑23.6 / 26.4°C x 0.05°C ) ASTM 45C:
Glass U Tube Viscometer to be purchased at extra cost
Load Frame. A MS welded frame of 50 KN capacity with AC motor and worm gear box setup within the base unit, traveling platen speed of 50.8mm/min on uniform speed. ...
Compaction Pedestal. ...
2 Nos of Compaction Rammer. ...
Breaking Head Assembly. ...
Specimen Extractor.
The test is intended for the measurement of the resistance to plastic flow of cylindrical specimens of bituminous paving mixture loaded on the lateral surface. For use with hot mixture containing asphalt or tar and aggregate upto 25.4 mm maximum sizes. The marshal stability test apparatus consists of following:
Specifications:
Marshal Load Frame 50kN capacity, Electrically Operated, with platen rate travel of 50.8mm/min. Safety cutoff switch is provided with the machine to avoid from overloading – 1No
Marshal Compaction Pedestal for compaction of 101.6mm (4”) Dia specimen – 1No
Breaking head assembly to accommodate specimen of 101.6mm Dia with dial gauge 0.01 x 25mm travel – 1 Set
Marshal Specimen Mould 101.6mm Dia (4”) complete with collar and base plate – 3 Nos
Marshal Compaction Hammer 4.53kg (10 lb) x 457mm (18”) drop height – 2 Nos
Proving Ring, 25kN or 30kN (as per requirement) capacity fitted with dial gauge with set of loading pads and calibration certificate in a nice wooden carrying case
Say bolt Viscometer, Electrically Heated, T72 for the empirical measurement of Say bolt Viscosity of petroleum products at specified temperatures between 70o F and 210o F. This is also used for determining the Saybolt Furol Viscosity of bituminous materials at temperatures of 250, 275, 300, 350, 400 and 450 F. It comprises one each of cylindrical Oil cup, Universal Tip, Furol Tip, Bath Fitted with immersion Heater mounted on a stand. Dimmer stat for temperature control, Stirrer with shield. Complete with insulated handle and thermometer support receiving flask, withdrawal tube, filter funnel, thermometer support for cup and circular spirit level. Suitable for operation on 230 V 50 Hz, Single Phase, A.C.
specifications and also per is 1448 (p: 60) & (p: 93) this apparatus is used for penetration test on a wide variety of materials. It consists of a head support mounted on a vertical rod which can be adjusted for height. A rack and pinion and pointer assembly provides fine adjustment of needle tip to sample and in corporate a slipping clutch mechanism which make reading of penetration and subsequent resetting a sample and accurate operation. The dial graduate from 0-400 in one tenth millimeter sub-division. The instrument is supplied with two sample containers & 2 wts.
Penetrometer apparatus with containers and weights having penetration needle (Bitumen)
Penetrometer apparatus with containers and weights having penetration CONE HOLLOW type (Grease)
same as above – but with Geared arrangement for moving the arm with geared unit.
Penetrometer with Brass Cone & Needle with DIGITAL TIMER DEVICE (Adjustable)
--- same as above—but with geared arrangement for moving the arm with geared unit.
Salient Features
Optional Accessories
Spare Penetration Needle (Pack of two)
Spare Penetration solid cone
Spare Penetration brass hollow cone
Grease worker hand operated
Grease worker hand operated big handle (Lever type)
A circular tray rotates in a vertical plane at a rate of approximately 100 r.p.m. by an electrical geared motor. 4 bottles of approximately 400 cc are mounted on this circular tray at an angle of 90 degrees to each other with their mouth towards centre of the tray. A time switch is provided.